Component E-H Implants with Tylan (Canada)
This treatment applies to the following species:(testosterone propionate, estradiol benzoate and tylosin tartrate)
BEEF HEIFERS
DIN 02245746
FOR VETERINARY USE ONLY
BEEF HEIFER IMPLANTS
20-DOSE CARTRIDGE BELT
For use with a Component Implanter.
Each CARTRIDGE BELT holds 20 doses of COMPONENT E-H Implants with Tylan. Each dose of 9 pellets consists of 8 pellets containing a total of 200 mg testosterone propionate USP and 20 mg estradiol benzoate plus 1 pellet containing 29 mg tylosin tartrate as a local antibacterial for reducing the incidence of abscess formation at the implant site. COMPONENT E-H Implants with Tylan provide complementary amounts of these hormones to help speed up the heifer’s weight gaining mechanism, and help improve feed efficiency. COMPONENT E-H Implants with Tylan are recommended for use in beef heifers weighing 185 to 365 kg.
Contraindications
COMPONENT E-H Implants with Tylan are not recommended for use in bulling or extremely restless animals. Not intended for use in breeding animals or dairy heifers. It is good husbandry to isolate bullers. COMPONENT E-H Implants with Tylan are neither intended nor recommended for use in ovariectomized (spayed) heifers.
Component E-H Implants with Tylan Caution
Bulling, vaginal and rectal prolapse, udder development, ventral edema and elevated tailheads have occasionally been reported in animals implanted with testosterone propionate and estradiol benzoate implants.
Warnings
Do not use in calves to be processed for veal. Implant COMPONENT E-H Implants with Tylan in the ear only; any other location may result in condemnation of the carcass. Do not attempt to salvage the implanted ear for human or animal food.Keep out of reach of children.
Storage
Do not freeze. Store at 10° to 27°C and protect from direct sunlight.Implanter Instructions
General Instructions
Study the instructions which should be followed carefully at all times. Avoid short cuts. Skin infections can be avoided by properly preparing implant site. During fly season use fly repellent on implant site. One designated team member should always do the implanting. Cleanliness of hands and instruments is important at all times.
Loading The Implanter
Load the implanter following the instructions supplied with each implanter.
Restrain The Animal
Speed of implantation as well as safety of handlers is best achieved by restraining animal in a squeeze chute using head restraint.
Prepare The Implant Site
Scrub the back side of the ear (implant site) with a piece of clean absorbent cotton which has been soaked with topical germicidal solution. Follow manufacturer’s directions on germicide for correct preparation and strength of solution. Avoid getting into animal’s eyes.
Where To Implant
The full contents of the cartridge (all 9 pellets) should be implanted beneath the skin on the back side of the middle one-third of the ear as illustrated in the drawing. The implant must not be closer to the head than the edge of auricular cartilage ring farthest from the head. The location of insertion of the needle is a point toward the tip of the ear and at least a needle length away from the intended deposition site. Avoid injuring the large arteries, veins and cartilage of the ear.
Insert The Needle
With one hand firmly grasp the ear. With other hand insert needle point through the skin and ease forward on a lateral plane until the entire length of the needle is under the skin.
Implant The Pellets
After inserting the needle fully in the correct implant position, squeeze the trigger fully as the needle is withdrawn from the ear. This properly deposits the implant in the needle track. This procedure should prevent breakage or crushing of pellets if otherwise forced into contact with tough fibrous-tissue underlying the skin. The length and total contact area of the single dose are designed to permit absorption of the hormones after implantation to stimulate good weight gain. Broken or crushed pellets may interfere with rates of gain and may lead to undesirable side effects such as noted in the CAUTIONS.
Clean The Needle
Disinfect the implanter needle with a germicidal solution prior to implanting the next animal. Disinfect the implanter needle with a germicidal solution prior to implanting the next animal.
Contains: 100 Implants; five (5) cartridge belts of 20 implants each, sealed in sanitary foil pouches.
U.S. Patent No. 5,874,098
Component, Tylan, Elanco and the diagonal bar logo are trademarks of Elanco or its affiliates.
Manufactured by Elanco Canada Limited, 150 Research Lane, Suite 120, Guelph, Ontario N1G 4T2
AH0338
25Jan2018
CPN: 1231141.1
1919 MINNESOTA COURT, SUITE 401, MISSISSAUGA, ON, L5N 0C9
Customer Service: | 800-265-5475 | |
Fax: | 519-821-7831 | |
Website: | www.elanco.ca | |
Email: | elancocanadacustomerservice@elancoah.com |
THIS SERVICE AND DATA ARE PROVIDED "AS IS". Animalytix assumes no liability, and each user assumes full risk, responsibility, and liability, related to its use of the Animalytix service and data. See the Terms of Use for further details. |
Copyright © 2024 Animalytix LLC. Updated: 2024-11-27