Skip to Content

Component TE-200 Implants with Tylan (Canada)

This page contains information on Component TE-200 Implants with Tylan for veterinary use.
The information provided typically includes the following:
  • Component TE-200 Implants with Tylan Indications
  • Warnings and cautions for Component TE-200 Implants with Tylan
  • Direction and dosage information for Component TE-200 Implants with Tylan

Component TE-200 Implants with Tylan

This treatment applies to the following species:
Manufacturer: Elanco

(trenbolone acetate, estradiol and tylosin tartrate)

STEERS

HEIFERS

DIN 02407760

IMPLANTS FOR INCREASED RATE OF WEIGHT GAIN AND IMPROVED FEED EFFICIENCY IN FEEDLOT STEERS AND HEIFERS (300 - 450 kg)

FOR FEEDLOT STEERS AND HEIFERS (300 - 450 kg)

FOR VETERINARY USE ONLY

20 DOSE CARTRIDGE BELT

For use with the Component Implanter

Description

COMPONENT TE-200 Implants with Tylan is an implant consisting of 10 small yellow pellets containing 200 mg of trenbolone acetate USP and 20 mg of estradiol USP, and one blue pellet containing 29 mg of tylosin tartrate.

INDICATIONS FOR USE:

This product contains trenbolone acetate and estradiol, in a slow-release delivery system, which increases rate of weight gain and improves feed efficiency in feedlot steers and heifers weighing 300 to 450 kg at the time of implantation. Tylan (tylosin tartrate) is included as a local antibacterial for reducing the incidence of abscess formation at the implant site.

NOTE:

The administration of COMPONENT TE-200 Implants with Tylan can result in decreased marbling compared to non-implanted steers and heifers. Studies in the U.S.A. have not demonstrated any advantage to the use of COMPONENT TE-200 over the use of COMPONENT TE-H (140 mg trenbolone acetate USP/14 mg estradiol USP) for improved rate of weight gain or feed efficiency in feedlot heifers.

Dosage: One implant containing 200 mg trenbolone acetate, 20 mg estradiol and 29 mg of tylosin tartrate is administered to each animal. The eleven pellets which make up the dosage of COMPONENT TE-200 Implants with Tylan are contained in one division of the multiple dose cartridge belt. Twenty doses are in each cartridge belt. The cartridge belt is designed to be used with a Component Implanter.

Directions For Use

For subcutaneous ear implantation in animals use a Component Implanter to implant the entire contents of one cartridge (11 pellets) per animal. The pellets must not be removed from the cartridge prior to implantation. The proper implantation technique is fully described. Never sacrifice careful, clean technique for speed of implantation.

Component TE-200 Implants with Tylan Caution

For use in feedlot steers and heifers only. Do not use in young calves (less than 300 kg body weight), spayed heifers or in heifers intended for subsequent breeding.

Warnings

Do not use in calves to be processed for veal. For use in feedlot steers and heifers only. Implant pellets in ear only. Do not attempt salvage of implanted site for human or animal food. Do not use in dairy cattle. Keep out of reach of children.

Storage

Store in a refrigerator (2° to 8°C) and protect from sunlight.

IMPLANTER INSTRUCTIONS:

General Instructions

Study the instructions which should be followed carefully at all times. Avoid short cuts. Skin infections can be avoided by properly preparing implant site. During fly season use fly repellent on implant site. One designated team member should always do the implanting. Cleanliness of hands and instruments is important at all times.

Loading The Implanter

Load the Implanter following the instructions supplied with each Implanter.

Restrain The Animal

Speed of implantation as well as safety of handlers is best achieved by restraining animal in a squeeze chute using head restraint. When implanting horned cattle, better control is obtained with additional use of nose tongs.

Prepare The Implant Site

Scrub the back side of the ear (implant site) with a piece of clean absorbent cotton which has been soaked with topical germicidal solution. Follow manufacturer’s directions on germicide for correct strength and preparation of solution. Avoid getting in animal’s eyes.

Where To Implant

The full contents of the cartridge (all 11 pellets) should be implanted beneath the skin on the back side of the middle one-third of the ear as illustrated in the drawing. The implant must not be closer to the head than the edge of auricular cartilage ring farthest from the head. The location for insertion of the needle is a point towards the tip of the ear at least a needle length away from the intended deposition site. Avoid injuring the arteries, veins and cartilage of the ear.

Insert The Needle

With one hand firmly grasp the ear. With other hand insert needle point through the skin and ease forward on a lateral plane until the entire length of the needle is under the skin.

Implant The Pellets

After inserting the needle fully in the correct implant position squeeze the trigger fully as the needle is withdrawn from the ear. This properly deposits the implant in the needle track. This procedure should prevent breakage or crushing of pellets if otherwise forced into contact with tough fibrous-tissue underlying the skin. The length and total contact area of the single dose are designed to permit absorption of the hormones after implantation to stimulate good weight gain. Broken or crushed pellets may interfere with rates of gain.

Clean The Needle

Disinfect the implanter needle with a germicidal solution prior to implanting the next animal.

Contains: 100 Implants; five (5) cartridge belts of 20 implants each, sealed in sanitary foil pouches.

U.S. Patent No. 5,874,098

Elanco, Component, Tylan and the diagonal bar are trademarks owned or licensed by Eli Lilly and Company, its subsidiaries or affiliates.

Manufactured by Elanco, Division Eli Lilly Canada, Inc., 150 Research Lane, Suite 120, Guelph, ON, Canada, N1G 4T2

AH0513

Revised 9-May-14

NAC No.: 1184048.1

ELANCO, Division Eli Lilly Canada Inc. & ELANCO CANADA LIMITED (successor to Novartis Animal Health Canada Inc.)
RESEARCH PARK CENTRE, 150 RESEARCH LANE, SUITE 120, GUELPH, ON, N1G 4T2
Telephone:   519-821-0277
Order Desk:   800-773-7603
Fax:   519-821-7831
Elanco Canada Limited Customer Service Telephone:   800-387-6325
Elanco Canada Limited Customer Service Fax:   800-827-5782
Website:   www.Elanco.ca
Every effort has been made to ensure the accuracy of the Component TE-200 Implants with Tylan information published above. However, it remains the responsibility of the readers to familiarize themselves with the product information contained on the Canadian product label or package insert.

Copyright © 2016 North American Compendiums. Updated: 2016-10-31

Hide