Skip to Content


Generic Name: fluciclovine f-18
Dosage Form: injection, solution

Indications and Usage for Axumin

Axumin is indicated for positron emission tomography (PET) in men with suspected prostate cancer recurrence based on elevated blood prostate specific antigen (PSA) levels following prior treatment.

Axumin Dosage and Administration

Radiation Safety - Drug Handling

Axumin is a radioactive drug and should be handled with appropriate safety measures to minimize radiation exposure during administration [see Warnings and Precautions (5.3)]. Use waterproof gloves and effective shielding, including syringe shields, when handling and administering Axumin.

Recommended Dose and Administration Instructions

The recommended dose is 370 MBq (10 mCi) administered as an intravenous bolus injection.

  • Inspect Axumin visually for particulate matter and discoloration before administration. Do not use the drug if the solution contains particulate matter or is discolored.
  • Use aseptic technique and radiation shielding when withdrawing and administering Axumin.
  • Calculate the necessary volume to administer based on calibration time and date, using a suitably calibrated instrument. The recommended maximum volume of injection of undiluted Axumin is 5mL.
  • Axumin may be diluted with Sodium Chloride Injection, 0.9%.
  • After the Axumin injection, administer an intravenous flush of sterile Sodium Chloride Injection, 0.9% to ensure full delivery of the dose.
  • Dispose of any unused drug in a safe manner in compliance with applicable regulations.

Patient Preparation Prior to PET Imaging

  • Advise the patient to avoid any significant exercise for at least one day prior to PET imaging.
  • Advise patients not to eat or drink for at least 4 hours (other than small amounts of water for taking medications) prior to administration of Axumin.

Image Acquisition Guidelines

Position the patient supine with arms above the head. Begin PET scanning 3 to 5 minutes after completion of the Axumin injection. It is recommended that image acquisition should start from mid-thigh and proceed to the base of the skull. Typical total scan time is between 20 to 30 minutes.

Image Display and Interpretation

Localization of prostate cancer recurrence in sites typical for prostate cancer recurrence is based on fluciclovine F 18 uptake in comparison with tissue background. For small lesions (less than 1cm in diameter) focal uptake greater than blood pool should be considered suspicious for prostate cancer recurrence. For larger lesions, uptake equal to or greater than bone marrow is considered suspicious for prostate cancer recurrence.

Radiation Dosimetry

The radiation absorbed doses estimated for adult patients following intravenous injection of Axumin are shown in Table 1. Values were calculated from human biodistribution data using OLINDA/EXM (Organ Level Internal Dose Assessment/Exponential Modeling) software.

The (radiation absorbed) effective dose resulting from the administration of the recommended activity of 370 MBq of Axumin is 8 mSv. For an administered activity of 370 MBq (10 mCi), the highest-magnitude radiation doses are delivered to the pancreas, cardiac wall, and uterine wall: 38 mGy, 19 mGy, and 17 mGy, respectively. If a CT scan is simultaneously performed as part of the PET procedure, exposure to ionizing radiation will increase in an amount dependent on the settings used in the CT acquisition.

Table 1: Estimated Radiation Absorbed Doses in Various Organs/Tissues in Adults who Received Axumin
Organ/Tissue Mean Absorbed Dose per Unit Administered Activity
Adrenal glands 16
Brain 9
Breasts 14
Gallbladder wall 17
Lower large intestine wall 12
Small intestine wall 13
Stomach wall 14
Upper large intestine wall 13
Heart wall 52
Kidneys 14
Liver 33
Lungs 34
Muscle 11
Ovaries 13
Pancreas 102
Red bone marrow 25
Osteogenic cells 23
Skin 8
Spleen 24
Testes 17
Thymus gland 12
Thyroid 10
Urinary bladder wall 25
Uterus 45
Total body 13
Effective dose 22 (microSv/MBq)

Dosage Forms and Strengths

Injection: supplied as a clear, colorless solution in a 30 mL multiple-dose vial containing 335 to 8200 MBq/mL (9 to 221 mCi/mL) fluciclovine F 18 at calibration time and date.



Warnings and Precautions

Risk for Image Misinterpretation

Image interpretation errors can occur with Axumin PET imaging. A negative image does not rule out the presence of recurrent prostate cancer and a positive image does not confirm the presence of recurrent prostate cancer. The performance of Axumin seems to be affected by PSA levels [See Clinical Studies (14)]. Fluciclovine F 18 uptake is not specific for prostate cancer and may occur with other types of cancer and benign prostatic hypertrophy in primary prostate cancer. Clinical correlation, which may include histopathological evaluation of the suspected recurrence site, is recommended.

Hypersensitivity Reactions

Hypersensitivity reactions including anaphylaxis may occur in patients who receive Axumin. Emergency resuscitation equipment and personnel should be immediately available.

Radiation Risks

Axumin use contributes to a patient's overall long-term cumulative radiation exposure. Long-term cumulative radiation exposure is associated with an increased risk for cancer. Ensure safe handling to minimize radiation exposure to the patient and health care providers [see Dosage and Administration (2.1)].

Adverse Reactions

Clinical Trials Experience

Because clinical trials are conducted under widely varying conditions, adverse reaction rates observed in the clinical trials of a drug cannot be directly compared to rates in the clinical trials of another drug and may not reflect the rates observed in practice. The clinical trial database for Axumin includes data from 877 subjects including 797 males diagnosed with prostate cancer. Most patients received a single administration of Axumin, a small number of subjects (n = 50) received up to five administrations of the drug. The mean administered activity was 370 MBq (range, 163 to 485 MBq).

Adverse reactions were reported in ≤1% of subjects during clinical studies with Axumin. The most common adverse reactions were injection site pain, injection site erythema and dysgeusia.



Risk Summary

Axumin is not indicated for use in females and there is no information on the risk of adverse development outcomes in pregnant women or animals with the use of fluciclovine F 18.


Risk Summary

Axumin is not indicated for use in females and there is no information of the presence of fluciclovine F 18 in human milk.

Pediatric Use

Safety and effectiveness have not been established in pediatric patients.

Geriatric Use

Of the total number of patients in clinical studies of Axumin, the average age was 66 years with a range of 21 to 90 years. No overall differences in safety or effectiveness were observed between older subjects and younger subjects.


In case of overdose of Axumin, encourage patients to maintain hydration and to void frequently to minimize radiation exposure.

Axumin Description

Chemical Characteristics

Axumin contains the fluorine 18 (F 18) labeled synthetic amino acid analog fluciclovine. Fluciclovine F 18 is a radioactive diagnostic agent used with PET imaging. Chemically, fluciclovine F 18 is (1r, 3r)-1-amino-3[18F]fluorocyclobutane-1-carboxylic acid. The molecular weight is 132.1 and the structural formula is:

Axumin is a sterile, non-pyrogenic, clear, colorless, hyperosmolal (approximately 500 - 540 mOsm/kg) injection for intravenous use. Each milliliter contains up to 2 micrograms of fluciclovine, 335 to 8200 MBq (9 to 221 mCi) fluciclovine F 18 at calibration time and date, and 20 mg trisodium citrate in water for injection. The solution also contains hydrochloric acid, sodium hydroxide and has a pH between 4 and 6.

Physical Characteristics

Fluorine 18 (F 18) is a cyclotron produced radionuclide that decays by positron emission (ß+ decay, 96.7%) and orbital electron capture (3.3%) to stable oxygen 18 with a physical half-life of 109.7 minutes. The positron can undergo annihilation with an electron to produce two gamma rays; the energy of each gamma ray is 511 keV (Table 2).

Table 2: Principal Radiation Produced from Decay of Fluorine 18 Radiation
Energy (keV) Abundance (%)
Positron 249.8 96.7
Gamma 511.0 193.5

External Radiation

The point source air-kerma coefficient for F 18 is 3.75 × 10-17 Gy m2/(Bq s). The first half-value thickness of lead (Pb) for F 18 gamma rays is approximately 6 mm. The relative reduction of radiation emitted by F 18 that results from various thicknesses of lead shielding is shown in Table 3. The use of 8 cm of Pb will decrease the radiation transmission (i.e., exposure) by a factor of about 10,000.

Table 3: Radiation Attenuation of 511 keV Gamma Rays by Lead Shielding
Shield Thickness cm of Lead (Pb) Coefficient of Attenuation
0.6 0.5
2 0.1
4 0.01
6 0.001
8 0.0001

Axumin - Clinical Pharmacology

Mechanism of action

Fluciclovine F 18 is a synthetic amino acid transported across mammalian cell membranes by amino acid transporters, such as LAT-1 and ASCT2, which are upregulated in prostate cancer cells. Fluciclovine F 18 is taken up to a greater extent in prostate cancer cells compared with surrounding normal tissues.


Following intravenous administration, the tumor-to-normal tissue contrast is highest between 4 and 10 minutes after injection, with a 61% reduction in mean tumor uptake at 90 minutes after injection.



Following intravenous administration, fluciclovine F 18 distributes to the liver (14% of administered activity), pancreas (3%), lung (7%), red bone marrow (12%) and myocardium (4%). With increasing time, fluciclovine F 18 distributes to skeletal muscle.


Across the first four hours post-injection, 3% of administered radioactivity was excreted in the urine. Across the first 24 hours post-injection, 5% of administered radioactivity was excreted in the urine.

Nonclinical Toxicology

Carcinogenesis, Mutagenesis, Impairment of Fertility


No long term studies in animals have been performed to evaluate the carcinogenic potential of fluciclovine.


Fluciclovine was not mutagenic in vitro in reverse mutation assay in bacterial cells and in chromosome aberration test in cultured mammalian cells, and was negative in an in vivo clastogenicity assay in rats after intravenous injection of doses up to 43 mcg/kg. However, fluciclovine F 18 has the potential to be mutagenic because of the F 18 radioisotope.

Impairment of Fertility

No studies in animals have been performed to evaluate potential impairment of fertility in males or females.

Clinical Studies

The safety and efficacy of Axumin were evaluated in two studies (Study 1 and Study 2) in men with suspected recurrence of prostate cancer based on rising PSA levels following radical prostatectomy and/or radiotherapy.

Study 1 evaluated 105 Axumin scans in comparison to histopathology obtained by biopsy of the prostate bed and biopsies of lesions suspicious by imaging. PET/CT imaging generally included the abdomen and pelvic regions. The Axumin images were originally read by on-site readers. The images were subsequently read by three blinded independent readers. Table 4 shows the performance of Axumin in the detection of recurrence in each patient scan and, specifically, within the prostatic bed and extra-prostatic regions, respectively. The results of the independent read were generally consistent with one another and confirmed the results of the on-site reads.

Table 4: Performance of Axumin in Patients with Biochemically Suspected Recurrent Prostate Cancer, at the Patient Level and at the Prostate Bed and Extraprostatic Region Levels
Reader 1 Reader 2 Reader 3
N = number of patient scans evaluated
Patient N = 104 N = 105 N = 99
  True Positive 75 72 63
  False Positive 24 23 13
  True Negative 5 7 15
  False Negative 0 3 8
Prostate Bed N = 98 N = 97 N = 96
  True Positive 58 56 47
  False Positive 29 26 15
  True Negative 10 12 24
  False Negative 1 3 10
Extraprostatic N = 28 N = 28 N = 25
  True Positive 25 26 22
  False Positive 2 2 2
  True Negative 0 0 0
  False Negative 1 0 1

The detection rate of Axumin seems to be affected by PSA levels [see Warnings and Precautions (5.1)]. In general, patients with negative scans had lower PSA values than those with positive scans. The detection rate (number with positive scans/total scanned) for patients with a PSA value of less than or equal to 1.78 ng/mL (1st PSA quartile) was 15/25, of which 11 were histologically confirmed as positive. In the remaining three PSA quartiles, the detection rate was 71/74, of which 58 were histologically confirmed. Among the 25 patients in the first PSA quartile, there were 4 false positive scans and 1 false negative scan. For the 74 patients with PSA levels greater than1.78 ng/mL, there were 13 false positive scans and no false negative scans.

Study 2 evaluated the concordance between 96 Axumin and C11 choline scans in patients with median PSA value of 1.44 ng/mL (interquartile range = 0.78 to 2.8 ng/mL). The C 11 choline scans were read by on-site readers. The Axumin scans were read by the same three blinded independent readers used for Study 1. The agreement values between the Axumin and C11 choline reads were 61%, 67% and 77%, respectively.

How Supplied/Storage and Handling

How Supplied

Axumin is supplied as a clear, colorless injection in a 30 mL multiple-dose glass vial containing approximately 26 mL solution of 335-8200 MBq/mL (9-221 mCi/mL) fluciclovine F 18 at calibration time and date.

30 mL sterile multiple-dose vial: NDC 69932-001-30

Storage and Handling

Store Axumin at controlled room temperature (USP) 20°C to 25°C (68°F to 77°F). Axumin does not contain a preservative. Store Axumin within the original container in radiation shielding.

This preparation is approved for use by persons under license by the Nuclear Regulatory Commission or the relevant regulatory authority of an Agreement State.

Patient Counseling Information

  • Instruct patients to avoid significant exercise for at least a day before the PET scan.
  • Instruct patients not to eat or drink for at least 4 hours before the PET scan (other than small amounts of water for taking medications).

Marketed by Blue Earth Diagnostics Ltd. Oxford, UK OX4 4GA
Axumin™ is a trademark of Blue Earth Diagnostics Ltd.
© 2016 Blue Earth Diagnostics Ltd – all rights reserved.

PRINCIPAL DISPLAY PANEL - 30 mL Multiple-Dose Vial Label




(fluciclovine F 18) injection
9 - 221 mCi/mL at End of Synthesis (EOS)
Diagnostic - For Intravenous Use Only
Expires 10 hours after EOS

Batch #: ________________________________

EOS Date: __________ EOS Time: __________

Activity @ EOS: ___________________ mCi

Concentration: ___________________ mCi/mL

Volume: ___________________ mL

Exp. Date: __________ Exp. Time: __________

fluciclovine f-18 injection, solution
Product Information
Product Type HUMAN PRESCRIPTION DRUG LABEL Item Code (Source) NDC:69932-001
Route of Administration INTRAVENOUS DEA Schedule     
Active Ingredient/Active Moiety
Ingredient Name Basis of Strength Strength
Fluciclovine F-18 (Fluciclovine F-18) Fluciclovine F-18 221 mCi  in 1 mL
Inactive Ingredients
Ingredient Name Strength
Sodium Citrate, Unspecified Form  
Hydrochloric Acid  
Sodium Hydroxide  
# Item Code Package Description
1 NDC:69932-001-30 30 mL in 1 VIAL, MULTI-DOSE
Marketing Information
Marketing Category Application Number or Monograph Citation Marketing Start Date Marketing End Date
NDA NDA208054 05/27/2016
Labeler - Blue Earth Diagnostics (219742530)
Name Address ID/FEI Operations
Name Address ID/FEI Operations
Name Address ID/FEI Operations
The University of Utah DBA Cyclotron Radiochemistry Lab, Huntsman Cancer Institute 018432646 MANUFACTURE(69932-001)
Revised: 08/2016
Blue Earth Diagnostics