Skip to Content

Succcinylcholine use while Breastfeeding

Succcinylcholine Levels and Effects while Breastfeeding

Summary of Use during Lactation

No information is available on the use of succinylcholine during breastfeeding. Because it is rapidly eliminated and poorly absorbed orally, it is not likely to reach the bloodstream of the infant or cause any adverse effects in breastfed infants.[1][2] A general anesthetic regimen that included succinylcholine for cesarean section caused a delay in the time to the first breastfeeding, but the part that succinylcholine played in this difference in outcome in unknown.

Drug Levels

Succinylcholine is rapidly hydrolyzed in maternal plasma and has a short half-life of about 3 to 5 minutes. It is unlikely to be excreted into milk or absorbed orally by the infant because of its highly polar nature.[1]

Maternal Levels. Relevant published information was not found as of the revision date.

Infant Levels. Relevant published information was not found as of the revision date.

Effects in Breastfed Infants

Relevant published information was not found as of the revision date.

Effects on Lactation and Breastmilk

A randomized, but nonblinded, study in women undergoing cesarean section compared epidural anesthesia with bupivacaine to general anesthesia with intravenous thiopental 4 mg/kg and succinylcholine 1.5 mg/kg for induction followed by nitrous oxide and isoflurane. The time to the first breastfeed was significantly shorter (107 vs 228 minutes) with the epidural anesthesia than with general anesthesia . This difference was probably caused by the anesthesia's effects on the infant, because the Apgar and neurologic and adaptive scores were significantly lower in the general anesthesia group of infants. It is not known what part succinylcholine played in this difference in outcome.[3]

Alternate Drugs to Consider

Atracurium, Ciatracurium, Rocuronium

References

1. Spigset O. Anaesthetic agents and excretion in breast milk. Acta Anaesthesiol Scand. 1994;38:94-103. PMID: 8171959

2. Howie WO, McMullen PC. Breastfeeding problems following anesthetic administration. J Perinat Educ. 2006;15:50-7. PMID: 17541461

3. Sener EB, Guldogus N, Karakaya D et al. Comparison of neonatal effects of epidural and general anesthesia for cesarean section. Gynecol Obstet Investig. 2003;55:41-55. PMID: 12624551

Succcinylcholine Identification

Substance Name

Succcinylcholine

CAS Registry Number

306-40-1

Drug Class

Muscle Relaxants

Neuromuscular Depolarizing Agents

Administrative Information

LactMed Record Number

706

Last Revision Date

20150310

Disclaimer

Information presented in this database is not meant as a substitute for professional judgment. You should consult your healthcare provider for breastfeeding advice related to your particular situation. The U.S. government does not warrant or assume any liability or responsibility for the accuracy or completeness of the information on this Site.

Disclaimer: This information is not intended as a substitute for professional judgment. You should consult your healthcare provider for breastfeeding advice related to your particular situation. Use of this website signifies your agreement to the Terms of Use and Online Privacy Policy.

Hide