Veterinary Product Information
Vet > React Test Kit

React Test Kit

This page contains information on React Test Kit for veterinary use.
The information provided typically includes the following:
  • React Test Kit Indications
  • Warnings and cautions for React Test Kit
  • Direction and dosage information for React Test Kit

React Test Kit

This treatment applies to the following species:
Manufacturer: PRN Pharmacal

Ethylene Glycol Test Kit

The REACT™ test kit is designed to detect the presence of ethylene glycol in the blood of cats and dogs.

Ethylene glycol in an enzyme catalyzed reaction causes the solution to change color.

Kit Components

This REACT™ test kit contains:

1 precision 40 µL pipette

1 transfer 1 mL pipette

1 yellow cap vial containing indicating powder

1 black cap vial containing buffer solution

1 white cap vial containing activating powder

Precautions And Warnings

Draw blood for this test before administration of any preparations containing propylene glycol, glycerol, sorbitol or mannitol. Failure could result in a false positive result. In addition, do not use thimerosol to preserve the sample as this may lead to a false positive. Propylene glycol may be found in some injectables, activated charcoal suspensions, semi-moist diets or non-toxic anti-freeze. Glycerol may be found in cough syrups, liqueurs or confections. Ethanol does not interfere with the results of this test; however, when combined with propylene glycol or glycerol it will produce a false positive. Read and understand the test indication, instruction and warnings before use.

Instructions For Test

1) Draw blood using either heparin or EDTA as an anticoagulant. Serum and plasma may also be used.

2) Use the 1 mL transfer pipette to transfer all the buffer solution from the black cap vial into the yellow cap indicating powder vial. Close cap and shake until all the powder is dissolved.

3) Use the same pipette to transfer all the resulting solution into the white cap activating powder vial. Close cap and shake until all the powder is dissolved.

4) Transfer half of the solution back into the empty black cap buffer vial to be used as a negative control.

5) Use the 40 µL precision pipette to transfer 40 µL of blood, serum or plasma into the white cap vial filled with solution. Close cap and shake until the solution is uniform and start timing the reaction.

6) If ethylene glycol is present the solution will turn purple within 6 minutes and be darker than the negative control.

7) Do not examine the vial after 10 minutes; the negative control may turn purple giving a false positive result.

Contents: One Kit

For Veterinary Use Only

Keep Out Of Reach Of Children And Pets

Not For Human Use

Store Refrigerated 2°c - 8°c (37°f - 46°f)

For Customer Service: (800) 874-9764

MANUFACTURED FOR PRN Pharmacal, An Employee-Owned Company, PENSACOLA, FLORIDA 32514

5-2009

Presentation

1 test kit.

Nac No.

10900350
PRN PHARMACAL
8809 ELY ROAD, PENSACOLA, FL, 32514
Telephone:   850-476-9462
Order Desk:   800-874-9764
Fax:   850-476-7087
Website:   www.prnpharmacal.com
Email:   gcushing@prnpharmacal.com
Every effort has been made to ensure the accuracy of the React Test Kit information published above. However, it remains the responsibility of the readers to familiarize themselves with the product information contained on the US product label or package insert.