Medication Guide App

Component E-H Implants with Tylan (Canada)

This page contains information on Component E-H Implants with Tylan for veterinary use.
The information provided typically includes the following:
  • Component E-H Implants with Tylan Indications
  • Warnings and cautions for Component E-H Implants with Tylan
  • Direction and dosage information for Component E-H Implants with Tylan

Component E-h Implants With Tylan

This treatment applies to the following species:
Manufacturer: Elanco

ah0338

din 02245746

beef Heifer Implants

VETERINARY USE ONLY

20-DOSE CARTRIDGE BELT1

For use with the COMPONENT One Gun®2.

Each CARTRIDGE BELT holds 20 doses of COMPONENT® E-H Implants with Tylan®. Each dose of 9 pellets consists of 8 pellets containing a total of 200 mg testosterone propionate USP and 20 mg estradiol benzoate plus 1 pellet containing 29 mg tylosin tartrate as a local antibacterial for reducing the incidence of abscess formation at the implant site. COMPONENT E-H Implants with Tylan provide complementary amounts of these hormones to help speed up the heifer’s weight gaining mechanism, and help improve feed efficiency. COMPONENT E-H Implants with Tylan are recommended for use in beef heifers weighing 185 to 365 kg.

Contraindications

COMPONENT E-H Implants with Tylan are not recommended for use in bulling or extremely restless animals. Not intended for use in breeding animals or dairy heifers. It is good husbandry to isolate bullers. COMPONENT E-H Implants with Tylan are neither intended nor recommended for use in ovariectomized (spayed) heifers.

Warning

Do not use in calves to be processed for veal. Implant COMPONENT E-H Implants with Tylan in the ear only; any other location may result in condemnation of the carcass. Do not attempt to salvage the implanted ear for human or animal food. Keep out of reach of children.

Component E-H Implants with Tylan Caution

Bulling, vaginal and rectal prolapse, udder development, ventral edema and elevated tailheads have occasionally been reported in animals implanted with testosterone propionate and estradiol benzoate implants.

Storage

Do not freeze. Store at 10° to 27° C and protect from direct sunlight.

Implanter Instructions

General Instructions

Study the instructions which should be followed carefully at all times. Avoid short cuts. Skin infections can be avoided by properly preparing implant site. During fly season use fly repellent on implant site. One designated team member should always do the implanting. Cleanliness of hands and instruments is important at all times.

Loading The Implanter

Load the implanter following the instructions supplied with each implanter.

Restrain The Animal

Speed of implantation as well as safety of handlers is best achieved by restraining animal in a squeeze chute using head restraint.

Prepare The Implant Site

Scrub the back side of the ear (implant site) with a piece of clean absorbent cotton which has been soaked with topical germicidal solution. Follow manufacturer’s directions on germicide for correct preparation and strength of solution. Avoid getting into animal’s eyes.

Where To Implant

The full contents of the cartridge (all 9 pellets) should be implanted beneath the skin on the back side of the middle one-third of the ear as illustrated in the drawing. The implant must not be closer to the head than the edge of auricular cartilage ring farthest from the head. The location of insertion of the needle is a point toward the tip of the ear and at least a needle length away from the intended deposition site. Avoid injuring the large arteries, veins and cartilage of the ear.

Insert The Needle

With one hand firmly grasp the ear. With other hand insert needle point through the skin and ease forward on a lateral plane until the entire length of the needle is under the skin.

Implant The Pellets

After inserting the needle fully in the correct implant position squeeze the trigger fully. As the needle is withdrawn from the ear, the controlled-pressure plunger action of the COMPONENT One Gun® properly deposits the implant in the needle track. This procedure should prevent breakage or crushing of pellets if otherwise forced into contact with tough fibrous-tissue underlying the skin. The length and total contact area of the single dose are designed to permit absorption of the hormones after implantation to stimulate good weight gain. Broken or crushed pellets may interfere with rates of gain and may lead to undesirable side effects such as noted in the CAUTION.

Clean The Needle

Disinfect the implanter needle with a germicidal solution prior to implanting the next animal.

Contains

100 implants; five (5) cartridge belts1 of 20 implants each, sealed in sanitary foil pouches.

1U.S. Patent No. 4,531,938

2U.S. Patent Nos. 4,762,515 & 5,522,797 - Ivy Animal Health, Inc.

COMPONENT® and COMPONENT One Gun® are trademarks of Ivy Animal Health, Inc.

Tylan®, *Elanco® and the diagonal colour bar are trademarks of Eli Lilly and Company

Manufactured by Ivy Animal Health, Inc., Overland Park, KS 66214 U.S.A.

Distributed by ELANCO®, Division Eli Lilly Canada Inc., Guelph, Ontario N1G 4T2

02 22 01 01

Nac No.

11840181
ELANCO ANIMAL HEALTH
Division Eli Lilly Canada Inc.

RESEARCH PARK CENTRE, 150 RESEARCH LANE, SUITE 120, GUELPH, ON, N1G 4T2
Telephone:   519-821-0277
Order Desk:   800-773-7603
Fax:   519-821-7831
Website:   www.Elanco.ca
Every effort has been made to ensure the accuracy of the Component E-H Implants with Tylan information published above. However, it remains the responsibility of the readers to familiarize themselves with the product information contained on the Canadian product label or package insert.

Copyright © 2013 North American Compendiums. Updated: 2013-05-17

Advertisement
Close

Recommended

(web3)